9.9.13 10Base-T Transmit Timing (Start of Packet)
SLLSEF8B – AUGUST 2013 – REVISED JANUARY 2014
Table 9-13. 10Base-T Transmit Timing (Start of Packet)
PARAMETER
TEST CONDITIONS
MIN
t1
Transmit Output Delay from the Falling Edge of TX_CLK 10Mbs MII mode
(1) (1) 1 bit time = 100ns in 10Mb/s.
TYP MAX UNIT(1)
5.8
bits
TX_CLK
TX_EN
TXD
t1
PMD Output Pair
Figure 9-13. 10Base-T Transmit Timing (Start of Packet)
9.9.14 10Base-T Transmit Timing (End of Packet)
Table 9-14. 10Base-T Transmit Timing (End of Packet)
PARAMETER
t1
End of Packet High Time (with ‘0’ ending bit)
t2
End of Packet High Time (with ‘1’ ending bit)
TEST CONDITIONS
MIN TYP MAX UNIT
250 310
ns
250 310
ns
TX_CLK
TX_EN
t1
PMD Output Pair
0
0
PMD Output Pair
t2
1
1
Figure 9-14. 10Base-T Transmit Timing (End of Packet)