English
Language : 

TLK111_14 Datasheet, PDF (102/110 Pages) Texas Instruments – PHYTER® Industrial Temperature 10/100Mbs Ethernet Physical Layer Transceiver
TLK111
SLLSEF8B – AUGUST 2013 – REVISED JANUARY 2014
9.9.25 Isolation Timing
www.ti.com
Table 9-25. Isolation Timing
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
t1
From Deassertion of S/W or H/W Reset to transition from Isolate to Normal
mode
71
ns
H/W or S/W Reset
MODE
t1
ISOLATE
NORMAL
Figure 9-25. Isolation Timing
T0365-01
9.9.26 25MHz_OUT Clock Timing
Table 9-26. 25MHz_OUT Clock Timing
PARAMETER
t1
25MHz_OUT(1) propagation delay
t2
25MHz_OUT(1) High Time
t3
25MHz_OUT(1) Low Time
TEST CONDITIONS
Relative to XI
MII mode
RMII mode
MII mode
RMII mode
(1) 25MHz_OUT characteristics are dependent upon the XI input characteristics.
MIN TYP MAX UNIT
8 ns
20
10
ns
20
10
XI
t2
t1
t3
25MHz_OUT
Figure 9-26. 25MHz_OUT Timing
T0366-01
102 Electrical Specifications