English
Language : 

LM3S101 Datasheet, PDF (119/445 Pages) List of Unclassifed Manufacturers – Microcontroller
Stellaris® LM3S101 Microcontroller
Register 30: Memory Management Fault Address (MMADDR), offset 0xD34
Note: This register can only be accessed from privileged mode.
The MMADDR register contains the address of the location that generated a memory management
fault. When an unaligned access faults, the address in the MMADDR register is the actual address
that faulted. Because a single read or write instruction can be split into multiple aligned accesses,
the fault address can be any address in the range of the requested access size. Bits in the Memory
Management Fault Status (MFAULTSTAT) register indicate the cause of the fault and whether
the value in the MMADDR register is valid (see page 113).
Memory Management Fault Address (MMADDR)
Base 0xE000.E000
Offset 0xD34
Type R/W, reset -
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
ADDR
Type R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ADDR
Type R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Reset
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Bit/Field
31:0
Name
ADDR
Type
R/W
Reset
-
Description
Fault Address
When the MMARV bit of MFAULTSTAT is set, this field holds the address
of the location that generated the memory management fault.
July 14, 2014
119