Module Name
main
main
The space preceding module names is required. Although formatted
for readability here, a single tab separates symbol and address.
The local symbols are scoped. When accessing the variable named
"count" in the source file module named "main.c", you would enter
"main:count". Notice that the module name of the source file "main.c"
is "main". see the following table.
Variable Name
You Enter:
count
main:count
line number 23
main: line 23
Location of the
HP 64869 Reader
Program
The HP 64869 Reader is located in the directory named \hp64700\bin
by default, along with the PC Interface. This directory must be in the
environment variable PATH for the HP 64869 Reader and PC Interface
to operate properly. This is usually defined in "\autoexec.bat" file.
Using the HP 64869
Reader from MS-DOS
The command name for the HP 64869 Reader is RD64869.EXE. You
can execute the HP 64869 Reader from the command line with the
command:
C:\HP64700\BIN\RD64869 [-q] <filename>
<RETURN>
where:
[-q]
specifies the "quiet" mode. This option suppresses
the display of messages.
<filename>
is the name of the file containing the HP 64869
format absolute program.
The command
C:\HP64700\BIN\RD64869 TESTPROG.ABS
will therefore create the files "TESTPROG.HPA" and
"TESTPROG.HPS".
A-8 File Format Readers