Drive Emulation
Reset to Target?
This configuration allows you to select whether or not the emulator
will drive the /RES signal to the target system during emulation reset.
no
Specifies that the emulator will not drive the /RES
signal during emulation reset.
yes
The emulator will drive an active level on the /RES
signal to the target system during emulation reset.
This configuration option is meaningful only when the emulator is
configured to respond to the /RES input to the target system
Refer to the "Enable /RES Input from Target?" configuration in this
chapter.
Trace Bus
Release Cycles?
You can direct the emulator to send bus release cycle data to emulation
analyzer or not to send it.
yes
When you enable tracing bus release cycles, bus
release cycles will appear as one analysis trace line.
no
Bus release cycles will not appear on analysis trace
list (display).
4-12 Configuring the Emulator