English
Language : 

HD6475368CP Datasheet, PDF (77/108 Pages) Agilent(Hewlett-Packard) – H8/536 Emulator PC Interface
Storing an
Emulator
Configuration
The PC Interface lets you store a particular emulator configuration so
that it may be re-loaded later. The following information is saved in
the emulator configuration.
Emulator configuration items.
Memory map.
Break conditions.
Trigger configuration.
Window specifications.
To store the current emulator configuration, select:
Config, Store
Enter the name of file to which the emulator configuration will be
saved.
Loading an
Emulator
Configuration
If you have previously stored an emulator configuration and wish to
re-load it into the emulator, select:
Config, Load
Enter the configuration file name and press Enter. The emulator will
be re-configured with the values specified in the configuration file.
Configuring the Emulator 4-17