Installing the
Target System
Probe
Caution
The emulator probe has a PLCC connector. The emulator is shipped
with a pin guard over the target system probe. This guard is designed
to prevent impact damage to the pins and should be left in place while
you are not using the emulator.
DAMAGE TO THE EMULATOR CIRCUITRY MAY RESULT
IF THESE PRECAUTIONS ARE NOT OBSERVED. The
following precautions should be taken while using the H8/536 emulator.
Power Down Target System. Turn off power to the user target
system and to the H8/536 emulator before inserting the user plug to
avoid circuit damage resulting from voltage transients or mis-insertion
of the user plug.
Verify User Plug Orientation. Make certain that Pin 1 of the target
system microprocessor socket and Pin 1 of the user plug are properly
aligned before inserting the user plug in the socket. Failure to do so
may result in damage to the emulator circuitry.
Protect Against Static Discharge. The H8/536 emulator contains
devices which are susceptible to damage by static discharge.
Therefore, operators should take precautionary measures before
handling the user plug to avoid emulator damage.
Protect Target System CMOS Components. If your target system
includes any CMOS components, turn on the target system first, then
turn on the H8/536 emulator; when powering down, turn off the
emulator first, then turn off power to the target system.
3-60 In-Circuit Emulation