HD6475368CP Datasheet, PDF (82/108 Pages) Agilent(Hewlett-Packard) – H8/536 Emulator PC Interface
To use the internal TRIG1 signal to connect the analyzer trigger to the
emulator break line, move the cursor to the highlighted "Analyzer"
field in the TRIG1 portion of the display, and use the Tab key to select
the "----->>" arrow which shows that the analyzer is driving TRIG1.
Next, move the cursor to the highlighted "Emulator" field and use the
Tab key to select the arrow pointing towards the emulator (<<-----);
this specifies that emulator execution will break into the monitor when
the TRIG1 signal is driven. The trigger configuration display is shown
in figure 5-1.
Note
Figure 5-1. Cross Trigger Configuration
If your emulator is configured with external analyzer, "Timing" cross
trigger options are displayed.
5-4 Using the Emulator