English
Language : 

HD6475368CP Datasheet, PDF (100/108 Pages) Agilent(Hewlett-Packard) – H8/536 Emulator PC Interface
Note
If TESTFILE.HPS and TESTFILE.HPA already exist but the
dates and times are later than the creation date/time for the HP
64869 format file, the current absolute file, TESTFILE.HPA,
is then loaded into the emulator.
Date/time checking is only done within the PC Interface. When
running the HP 64869 Reader at the MS-DOS command line prompt,
the HP 64869 Reader will always update the absolute and symbol files.
When the HP 64869 Reader operates on a file, a status message will be
displayed indicating that it is reading a HP 64869 format file. When
the HP 64869 Reader completes its processing, another message will
be displayed indicating the absolute file is being loaded.
If the Reader Won’t
Run
If your program is very large, then the PC Interface may run out of
memory while attempting to create the database file used. If this
condition occurs, you will need to exit the PC Interface and execute the
program at the command prompt to create the files that are downloaded
to the emulator.
Including RD64869 in
a Make File
You may wish to incorporate the "RD64869" process as the last step in
your "make" file, or as a step in your construction process, so as to
eliminate the possibility of having to exit the PC Interface due to space
limitations describe above. If the "-.HPA" and "-.HPS" files are not
current, the process of loading an HP 64869 format file will
automatically create them.
A-10 File Format Readers