English
Language : 

HD6475368CP Datasheet, PDF (81/108 Pages) Agilent(Hewlett-Packard) – H8/536 Emulator PC Interface
/EXECUTE
Active low. This line serves as a global interrupt
signal. Upon reception of an enabled /EXECUTE
signal, each emulator is to interrupt whatever it is
doing and execute a previously defined process,
typically, run the emulator or start a trace
measurement.
Running the
Emulator at
/EXECUTE
Before you can specify that the emulator run upon receipt of the
/EXECUTE signal, you must enable CMB interaction. To do this,
select:
Config, General
Use the arrow keys to move the cursor to the "Enable CMB
Interaction? [n]" question, and type "y". Use the Enter key to exit out
of the lower right-hand field in the configuration display.
To specify that the emulator begin executing a program upon reception
of the /EXECUTE signal, select:
Processor, CMB, Go
At this point you may either select the current program counter, or you
may select a specific address.
The command you enter is saved and is executed when the /EXECUTE
signal becomes active. Also, you will see the message "ALERT: CMB
execute; run started".
Breaking on the
Analyzer Trigger
To cause emulator execution to break into the monitor when the
analyzer trigger condition is found, you must modify the trigger
configuration. To access the trigger configuration, select:
Config, Trigger
The trigger configuration display contains two diagrams, one for each
of the internal TRIG1 and TRIG2 signals.
Using the Emulator 5-3