English
Language : 

XRT72L71 Datasheet, PDF (82/102 Pages) Exar Corporation – DS3 ATM UNI/CLEAR CHANNEL FRAMER
XRT72L71
DS3 ATM UNI/CLEAR CHANNEL FRAMER
REV. 1.1.0
áç
REGISTER 78
TABLE 79: RX CP INTERRUPT ENABLE REGISTER
RX CP INTERRUPT ENABLE REGISTER
HEX ADDRESS: 0X4E
BIT
FUNCTION
7-3 Unused
TYPE
RO
DEFAULT
0
DESCRIPTION-OPERATION
0: “Receipt of OAM Cell” Interrupt is disabled.
1: “Receipt of OAM Cell” Interrupt is enabled.
2 OAM Interrupt Enable
R/W
0
NOTE: This bit-field is only active if the XRT72L71 is operating in the “ATM
UNI” Mode.
1 LCD Interrupt Enable
0: “Change in LCD (Loss of Cell Delineation) Condition” Interrupt is dis-
abled.
R/W
0
1: “Change in LCD Condition” Interrupt is enabled.
NOTE: This bit-field is only active if the XRT72L71 is operating in the “ATM
UNI” Mode.
0 HEC Error Interrupt Enable R/W
0: “Detection of HEC Byte Error” Interrupt is disabled.
1: “Detection of HEC Byte Error” Interrupt is enabled.
0
NOTE: This bit-field is only active if the XRT72L71 is operating in the “ATM
UNI” Mode.