LM3S6110 Datasheet, PDF (446/610 Pages) Texas Instruments – Stellaris® LM3S6110 Microcontroller | |||
|
◁ |
Ethernet Controller
12.4
12.4.1
â A frame transmission error has occurred
â A frame has been transmitted successfully
â A frame has been received with inadequate room in the RX FIFO (overrun)
â A frame has been received with one or more error conditions (for example, FCS failed)
â An MII management transaction between the MAC and PHY layers has completed
â One or more of the following PHY layer conditions occurs:
â Auto-Negotiate Complete
â Remote Fault
â Link Status Change
â Link Partner Acknowledge
â Parallel Detect Fault
â Page Received
â Receive Error
â Jabber Event Detected
Initialization and Configuration
The following sections describe the hardware and software configuration required to set up the
Ethernet Controller.
Hardware Configuration
Figure 12-4 on page 447 shows the proper method for interfacing the Ethernet Controller to a
10/100BASE-T Ethernet jack.
446
June 18, 2012
Texas Instruments-Production Data
|
▷ |