System Control
Bit/Field
2
1
0
Name
UART2
UART1
UART0
Type
R/W
R/W
R/W
Reset
0
0
0
Description
UART2 Reset Control
When this bit is set, UART module 2 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
UART1 Reset Control
When this bit is set, UART module 1 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
UART0 Reset Control
When this bit is set, UART module 0 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
288
January 20, 2012
Texas Instruments-Production Data