Si5328
Register 55.
Bit
Name
Type
D7
D6
Reserved
R
D5
D4
D3
CLKIN2RATE_[2:0]
R/W
D2
D1
D0
CLKIN1RATE[2:0]
R/W
Reset value = 0000 0000
Bit
Name
Function
7:6
Reserved
Reserved.
5:3 CLKIN2RATE[2:0] CLKIN2RATE[2:0].
CKINn frequency selection for FOS alarm monitoring.
000: 10–27 MHz
001: 25–54 MHz
010: 50–105 MHz
011: 95–215 MHz
100: 190–435 MHz
101: 375–710 MHz
110: Reserved
111: Reserved
2:0 CLKIN1RATE [2:0] CLKIN1RATE[2:0].
CKINn frequency selection for FOS alarm monitoring.
000: 10–27 MHz
001: 25–54 MHz
010: 50–105 MHz
011: 95–215 MHz
100: 190–435 MHz
101: 375–710 MHz
110: Reserved
111: Reserved