English
Language : 

4509 Datasheet, PDF (95/142 Pages) Renesas Technology Corp – SINGLE-CHIP 4-BIT CMOS MICROCOMPUTER
4509 Group
MACHINE INSTRUCTIONS (INDEX BY ALPHABET) (continued)
SNZT1 (Skip if Non Zero condition of Timer 1 interrupt request flag)
Instruction
code
D9
D0
Number of
1010000000
280
2
16
words
1
Number of
cycles
1
Flag CY
–
Skip condition
V12 = 0: (T1F) = 1
Operation:
V12 = 0: (T1F) = 1 ?
(T1F) ← 0
V12 = 1: SNZT1 = NOP
(V12 = bit 2 of interrupt control register V1)
Grouping: Timer operation
Description: When V12 = 0 : Clears (0) to the T1F flag
and skips the next instruction when timer 1
interrupt request flag T1F is “1.” When the
T1F flag is “0,” executes the next instruc-
tion.
When V12 = 1 : This instruction is equiva-
lent to the NOP instruction.
SNZT2 (Skip if Non Zero condition of Timer 2 interrupt request flag)
Instruction
code
D9
D0
Number of
1010000001
281
2
16
words
1
Number of
cycles
1
Flag CY
–
Skip condition
V13 = 0: (T2F) = 1
Operation:
V13 = 0: (T2F) = 1 ?
(T2F) ← 0
V13 = 1: SNZT2 = NOP
(V13 = bit 3 of interrupt control register V1)
Grouping: Timer operation
Description: When V13 = 0 : Clears (0) to the T2F flag
and skips the next instruction when timer 2
interrupt request flag T2F is “1.” When the
T2F flag is “0,” executes the next instruc-
tion.
When V13 = 1 : This instruction is equiva-
lent to the NOP instruction.
SRST (System ReSet)
Instruction
code
D9
D0
Number of Number of Flag CY
0000000001
001
words
cycles
2
16
1
1
–
Skip condition
–
Operation: System reset
Grouping: Other operation
Description: System reset occurs.
SST (Serial interface transmission/reception STart)
Instruction
code
D9
D0
Number of Number of Flag CY
1010011110
29E
words
cycles
2
16
1
1
–
Skip condition
–
Operation:
(SIOF) ← 0
Serial interface transmit/receive starting
Grouping: Serial interface operation
Description: Clears (0) to SIOF flag and starts serial in-
terface.
Rev.1.02 2006.12.22 page 95 of 140
REJ03B0147-0102