Hibernation Module
6.4
6.4.1
6.4.2
6.4.3
Initialization and Configuration
The Hibernation module can be set in several different configurations. The following sections show
the recommended programming sequence for various scenarios. The examples below assume that
a 32.768-kHz oscillator is used, and thus always show bit 2 (CLKSEL) of the HIBCTL register set
to 1. If a 4.194304-MHz crystal is used instead, then the CLKSEL bit remains cleared. Because the
Hibernation module runs at 32.768 kHz and is asynchronous to the rest of the system, software
must allow a delay of tHIB_REG_WRITE after writes to certain registers (see “Register Access
Timing” on page 240). The registers that require a delay are listed in a note in “Register
Map” on page 245 as well as in each register description.
Initialization
The Hibernation module clock source must be enabled first, even if the RTC feature is not used. If
a 4.194304-MHz crystal is used, perform the following steps:
1. Write 0x40 to the HIBCTL register at offset 0x10 to enable the crystal and select the divide-by-128
input path.
2. Wait for a time of tXOSC_SETTLE for the crystal to power up and stabilize before performing any
other operations with the Hibernation module.
If a 32.678-kHz oscillator is used, then perform the following steps:
1. Write 0x44 to the HIBCTL register at offset 0x10 to enable the oscillator input.
2. No delay is necessary.
The above is only necessary when the entire system is initialized for the first time. If the processor
is powered due to a wake from hibernation, then the Hibernation module has already been powered
up and the above steps are not necessary. The software can detect that the Hibernation module
and clock are already powered by examining the CLK32EN bit of the HIBCTL register.
RTC Match Functionality (No Hibernation)
Use the following steps to implement the RTC match functionality of the Hibernation module:
1. Write the required RTC match value to one of the HIBRTCMn registers at offset 0x004 or 0x008.
2. Write the required RTC load value to the HIBRTCLD register at offset 0x00C.
3. Set the required RTC match interrupt mask in the RTCALT0 and RTCALT1 bits (bits 1:0) in the
HIBIM register at offset 0x014.
4. Write 0x0000.0041 to the HIBCTL register at offset 0x010 to enable the RTC to begin counting.
RTC Match/Wake-Up from Hibernation
Use the following steps to implement the RTC match and wake-up functionality of the Hibernation
module:
1. Write the required RTC match value to the HIBRTCMn registers at offset 0x004 or 0x008.
2. Write the required RTC load value to the HIBRTCLD register at offset 0x00C.
3. Write any data to be retained during power cut to the HIBDATA register at offsets 0x030-0x12C.
244