TCM4400 Datasheet, PDF (20/72 Pages) Texas Instruments – GSM/DCS BASEBAND AND VOICE A/D AND D/A RF INTERFACE CIRCUIT | |||
|
◁ |
2.5.5 I and Q Channels Matching â Baseband Downlink Path
PARAMETER
TEST CONDITIONS MIN
ÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃ Gain matching between channels
0 Hz to 96 kHz 18-kHz sine wave
â 0.5
ÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃÃ Delay matching between channels 0 Hz to 96 kHz 18-kHz sine wave
â5
TYP MAX UNIT
0.5 dB
5 ns
2.5.6 Baseband Downlink Path Global Characteristics
PARAMETER
MIN TYP MAX UNIT
Power supply rejection, 0 Hz â100 kHz band
60
dB
2.6 Timing Requirements of Baseband Downlink Path (See Figure 3â2)
MIN NOM MAX UNITâ
tsu4 Setup time, BDLONâ to BCALâ
tw3 Pulse duration, BCAL
tsu5 Setup time BCAL low before BENAâ
tw4 Pulse duration, BENA high
5
60
0
N effective duration of burst
controlled by BENA
N
µs
µs
µs
1/4-bit
tsu6 Setup time, BENAâ before DATAOUT valid
th4 Hold time, DATAOUT valid after BENAâ
th5 Hold time, BDLON low after BENA low
â Value given is for system information only.
24.3
28 µs
3.7 µs
0
µs
2.7 Automatic Power Control (APC)
2.7.1 APC Level (8-bit DAC)
PARAMETER
Integral nonlinearity (best fitting)
Differential nonlinearity
Settling time
TEST CONDITIONS
Shaper at maximum
full-scale load 10 kâ¦, 50 pF
MIN TYP MAX UNIT
â1
1 LSB
â1
1 LSB
10 µs
2.7.2 APC Shaper (5-bit DAC)
PARAMETER
Integral nonlinearity (best fitting)
Differential nonlinearity
Settling timeâ
â Value given is for system information only.
MIN TYP MAX UNIT
â1
1 LSB
â1
1 LSB
1 µs
2â6
|
▷ |