SNLS433C – NOVEMBER 2012 – REVISED JANUARY 2015
Recommended Timing Requirements for the Serial Control Bus (continued)
Over 3.3-V supply and temperature ranges unless otherwise specified.(1)(2)(3)
MIN
tr
SCL & SDA Rise Time, see
Figure 9
Standard Mode
Fast Mode
tf
SCL & SDA Fall Time, see
Figure 9
Standard Mode
Fast mode
NOM
MAX
1000
300
300
300
UNIT
ns
ns
ns
ns
6.9 Timing Requirements
tR
tF
tSU;DAT
tHD;DAT
tSP
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time — READ
Hold Up Time — READ
Input Filter
SDA, RPU = 10 kΩ, Cb ≤ 400 pF, see Figure 9
See Figure 9
See Figure 9
RxIN[3:0]+
RxCLKIN+
VTL
VCM
RxIN[3:0]-
RxClkIN-
VTH
MIN NOM MAX UNIT
430
ns
20
ns
560
ns
615
ns
50
ns
+VOD/4
-VOD/4
GND
Figure 1. FPD-Link DC VTH/VTL Definition
RxCLKIN 18
RxIN[3:0]
I2S
GPIO[1:0]
DOUT+
D
DOUT-
100 nF
100:
100 nF
Differential probe
Input Impedance û 100 k:
CL ú 0.5 pf
BW û 3.5 GHz
SCOPE
BW û 4GHz
Single Ended
VOD
DOUT-
DOUT+
VOD+
VOD-
| VOS
0V
VOD+
Differential
(DOUT+) - (DOUT-)
0V
VOD-
Figure 2. Serializer VOD DC Output
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: DS90UH927Q-Q1
Submit Documentation Feedback