recommended operating conditions
Supply voltage, VCC
Input voltage, VI
High-level input voltage, VIH
Low-level input voltage, VIL
Input transition (rise and fall) time, tt
Operating ambient temperature range, TA
Virtual junction temperature, TJ
TL16PIR552
DUAL UART WITH DUAL IrDA AND
1284 PARALLEL PORT
SLLS222A – DECEMBER 1995 – REVISED AUGUST 1996
MIN NOM
4.75
5
0
2
–0.5
0
0
25
0
25
MAX
5.25
VCC
VCC
0.8
25
70
115
UNIT
V
V
V
V
ns
°C
°C
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
COMMERCIAL
UNIT
MIN MAX
VOH
VOL
VIT+
VIT –
Vhys
IOZ
High-level output voltage
Low-level output voltage
Positive-going input threshold voltage‡
Negative-going input threshold voltage‡
Hysteresis‡ (VIT+ – VIT –)
3-state-output Hi-Z current
IOH = Rated†
IOL = Rated†
TTL compatible
TTL compatible
TTL compatible
VI = VCC or GND§
VCC – 0.8
V
0.5 V
2V
0.8
V
0.25 0.7 V
±10 µA
IIL
Low-level input current
VI = GND
– 1 µA
IIH
High-level input current
VI = VCC
1 µA
† 12 mA for 1284 control, 3 mA for all other outputs
‡ Applies to external input and bidirectional buffers with hysteresis. All input buffers have hysteresis.
§ A 3-state or open-drain output must be in the high-impedance state.
NOTE 4: All 1284 output and data terminals are low-noise TTL 12 mA drivers. The type of the driver, push/pull or open drain, is switched
dynamically based on the 1284 mode.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265