ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)
Supply voltage(2), VDD, VDDA
Supply voltage(2), VDDQ
Supply voltage(2), VDDB
Supply voltage(2), VDDT
Input Voltage, VI (LVCMOS)
Input Voltage, VI (HSTL CLASS 1)
Electrostatic Discharge
Storage temperature, Tstg
Operating free-air temperature range, TA
UNIT
-0.3 V to 1.5 V
-0.3 V to 2.5 V
-0.3 V to 3 V
-0.3 V to 2 V
-0.5 V to 3 V
-0.5 V to 2 V
HBM: 2 kV, CDM: 750 V
-65°C to 150°C
0°C to 70°C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
VDD, Core supply voltage
VDDB, Bias supply voltage
VDDT, Bias supply voltage
VDDQ, I/O supply voltage
VDDA, Analog supply voltage
IDD, Core supply current
IDDQ, I/O supply current
IDDB, Bias supply current
IDDA, Analog supply current
PD, Total power consumption
VREF, Input reference voltage(1)
ISDA, Analog shutdown current
ISDD, Core shutdown current
LVCMOS I/O
HSTL Class 1
Rω = 156.25 MHz
Rω = 156.25 MHz
Rω = 156.25 MHz
Rω = 156.25 MHz
Rω = 156.25 MHz
HSTL Class 1
MIN
NOM
MAX UNIT
1.14
1.2
1.26
V
2.37
2.5
2.63
V
1.14
1.2
1.26
V
1.4
1.5
1.6
V
1.14
1.2
1.26
V
770
mA
415
mA
35
mA
240
mA
2.09
2.4
W
0.71
0.75
0.79
V
0.5
mA
11
mA
(1) The value of VREF may be selected to provide optimum noise margin in the system. Typically the value of VREF is expected to be 0.5 x
VDDQ of the transmitting device and VREF is expected to track variations in VDDQ. Peak-to-peak ac noise on VREF may not exceed ± 2%
VREF (dc).
REFERENCE CLOCK TIMING REQUIREMENTS (REFCLKP/N)(1)
over operating free-air temperature range (unless otherwise noted)
PARAMETER
Frequency
Accuracy
Duty cycle
Jitter
TEST CONDITIONS
Minimum data rate
Maximum data rate
Random and deterministic
MIN
TYP-0.01%
TYP-0.01%
-200
40%
TYP
125
156.25
50%
MAX
TYP+0.01%
TYP+0.01%
200
60%
40
UNIT
MHz
ppm
ps
(1) This clock should be crystal referenced to meet the requirements of the above table. Contact your local TI sales office for specific
clocking recommendations.