Table 71. SERDES_JOGCOM_CONTROL(1)
Address:0x808E
Default:0x0000
Bit(s)
Name
Description
4/5.32910.15: JOGCOM[7:0]
8
Jog alignment/ Comma enable bit (one bit per lane).
When CFG[7] is set to 0, this bit acts as comma alignment enable control.
• JOGCOM[i] = 0 : Comma alignment enabled for lane i
• JOGCOM[i] = 1 : Comma alignment disabled for lane i
Access
RW
When CFG[7] is set to 1, this bit induces alignment jog on
lanes 7..0
• JOGCOM[i] = 0 : Alignment jog disabled for lane i
• JOGCOM[i] = 1 : Alignment jog enabled for lane i
(1) These control bits are for vendor testing only. Customer should leave them at their default values
Table 72. DIE_ID_3
Address:0x8090
Bit(s)
Name
Description
4/5.32912.15: Die ID [63:48]
0
Bits [63:48] of the Die ID. Unique TI DIE identifier.
Default:0x0000
Access
RO
Table 73. DIE_ID_2
Address:0x8091
Bit(s)
Name
Description
4/5.32913.15: Die ID [47:32]
0
Bits [47:32] of the Die ID. Unique TI DIE identifier.
Default:0x0000
Access
RO
Table 74. DIE_ID_1
Address:0x8092
Bit(s)
Name
Description
4/5.32914.15: Die ID [31:16]
0
Bits [31:16] of the Die ID. Unique TI DIE identifier.
Default:0x0000
Access
RO
Table 75. DIE_ID_0
Address:0x8093
Bit(s)
Name
Description
4/5.32915.15: Die ID [15:0]
0
Bits [15:0] of the Die ID. Unique TI DIE identifier.
Default:0x0000
Access
RO