Table 67. Asynchronous Frequency Ramp Mode
CFG[9]
X
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
TESTCFG[7:4]
XXX0
0001
0011
0101
0111
1001
1011
1101
1111
0001
0011
0101
0111
1001
1011
1101
1111
AFR
www.ti.com
RAMP MODE
Disabled
- 521 ppm
+ 521 ppm
- 390 ppm
+ 390 ppm
- 195 ppm
+ 195 ppm
- 98 ppm
+ 98 ppm
- 695 ppm
+ 695 ppm
- 520 ppm
+ 520 ppm
- 260 ppm
+ 260 ppm
- 130 ppm
+ 130 ppm
Bit(s)
4/5.32907.4
4/5.32907.3
4/5.32907.2
4/5.32907.1
4/5.32907.0
Table 68. REDUNDANCY_CONTROL
Address:0x808B
Default:0x0000
Name
Description
IDLE
When set, during non retime mode, generates Idle on all lanes of the
redundant XAUI channel.
A/B select
When set, channel A is selected as primary else channel B acts as primary
channel.
RETIME
When set, device will go into retime mode else non retime mode. (Default 0)
XGMII Tristate
When set, puts into a high-impedance state the data outputs on the XGMII
side
Transition code
Output code to be sent during transition from A to B or B to A. When 0 FE,
when 1 LF is transmitted.
Access
RW
Table 69. TRANSITION_TIME_CONTROL
Address:0x808C
Default:0x0000
Bit(s)
Name
Description
4/5.32908.15: Transition time
0
Transition time interval control in 312.5 XGMII clock intervals.
Access
RW
Table 70. REDUNDANCY_COMPOSITE_STATUS
Bit(s)
4/5.32909.15
4/5.32909.14
4/5.32909.13
Address:0x808D
Default:0x0000
Name
Description
IDLE composite
When high, indicates that Idle mode is selected through the REDUN-
DANCY_CONTROL register on page 56 or through the device input pin.
A_B composite
When high, indicates that lane A is selected as primary lane. It is OR ed
version of the REDUNDANCY_CONTROL register bit on page 56 and the
device input pin.
RETIME composite
When high, indicates that device is in RETIME mode. It is OR ed version of
the REDUNDANCY_CONTROL register bit on page 56 and the device input
pin.
Access
RO