English
Language : 

CC2510_15 Datasheet, PDF (19/245 Pages) Texas Instruments – Low-Power SoC (System-on-Chip) with MCU, Memory,2.4 GHz RF Transceiver, and USB Controller
CC2511F8 - Not Recommended for New Designs
CC2510Fx / CC2511Fx
Parameter
PLL turn-on / hop time4
RX to TX switch 4
TX to RX switch 4
PLL calibration time4
Min Typ
Max
Unit Condition/Note
72.4 75.2 81.4
81.4 81.4 81.4
29.0 30.1 32.6
32.6 32.6 32.6
30.0 31.1 33.6
33.6 33.6 33.6
707 735
796
796 796
796
µs
CC2510Fx
CC2511Fx
Time from leaving the IDLE state until arriving in the RX,
FSTXON, or TX state, when not performing calibration.
Crystal oscillator running.
µs
CC2510Fx
CC2511Fx
Settling time for the 1∙IF frequency step from RX to TX
µs
CC2510Fx
CC2511Fx
Settling time for the 1∙IF frequency step from TX to RX
µs
CC2510Fx
CC2511Fx
Calibration can be initiated manually or automatically
before entering or after leaving RX/TX.
Note: This is the PLL calibration time given that
TEST0=0x0B and FSCAL3.CHP_CURR_CAL_EN=10
(max calibration time). Please see DN110 [11] for more
details
Table 16: Frequency Synthesizer Parameters
6.9 Analog Temperature Sensor
TA= 25°C, VDD = 3.0V if nothing else stated. All measurement results are obtained using the
CC2510EM reference designs ([1]).
Parameter
Min Typ Max Unit Condition/Note
Output voltage at −40°C
Output voltage at 0°C
Output voltage at 40°C
Output voltage at 80°C
Temperature coefficient
Error in calculated
temperature, calibrated
Current consumption
increase when enabled
0.654
V
0.750
V
0.848
V
0.946
V
2.43
−2 *
0
mV/°C Fitted from −20°C to 80°C
2*
°C From −20°C to 80°C when using 2.43 mV/°C, after 1-point
calibration at room temperature
* The indicated minimum and maximum error with 1-point
calibration is based on measured values for typical
process parameters
0.3
mA
Table 17: Analog Temperature Sensor Parameters
4 fRef = fXOSC for CC2510Fx and fRef = f fXOSC xosc/2 for CC2511Fx
For CC2510Fx Min figures are given using fXOSC = 27 MHz. Typ figures are given using fXOSC = 26 MHz,
and Max figures are given using fXOSC = 24 MHz. For CC2511Fx, fXOSC = 48 MHz The system clock
frequency is equal to fRef and the data rate is 250 kBaud. See DN110 [11] for more details.
SWRS055G
Page 19 of 236