English
Language : 

1EDI2001AS_15 Datasheet, PDF (83/135 Pages) Infineon Technologies AG – Single Channel Isolated Driver for Inverter Systems AD Step
Field
Bits
CER1
2
LMI
1
P
0
1) This bit is not set after a reset event
EiceDRIVER™ SIL
1EDI2001AS
Register Description
Type
rhs
rh
rh
Description
Communication Error Primary Flag
This indicates if a loss of communication event1) with the
secondary chip has been detected by the primary chip.
0B: No event has been detected.
1B: An event has been detected.
This bit is sticky.
Note: This bit can not be cleared while an error condition
is active (bit PSTAT2.SRDY cleared).
Last Message Invalid Notification
This bit indicates if the last received SPI Message was
correctly processed by the device.
0B: Previous Message was processed correctly.
1B: Previous Message was discarded.
Parity Bit
Odd Parity Bit.
Datasheet
83
Hardware Description
Rev. 3.1, 2015-07-30