English
Language : 

M0564LE4AE Datasheet, PDF (112/161 Pages) List of Unclassifed Manufacturers – 32-BIT MICROCONTROLLER
M0564
point 1
point 2 point 3 point 4
point 5
PERIOD
PERIOD DATA0
PERIOD DATA1
PBUF
PERIOD DATA0
PERIOD DATA1
CMPDAT
CMPDAT DATA1
CMPBUF
PERIOD DATA1
PERIOD DATA0
PERIOD DATA2
CMPDAT DATA1
CMPDAT DATA0
0x10000
CMPU
CMPDAT DATA1
CNT
point 6
PERIOD DATA2
PERIOD DATA2
Note:
Write
Load
Figure 6.17-6 Period Loading Mode with Up Count Type
6.17.3.9 Immediately Loading Mode
When the IMMLDEN (TIMERx_PWMCTL[9]) bit set to 1, PWM operates at immediately loading
mode. In immediately loading mode, when user update PERIOD (TIMERx_PWMPERIOD[15:0])
or CMP (TIMERx_PWMCMPDAT[15:0]), PERIOD or CMP will be load to active PBUF
(TIMERx_PWMPBUF[15:0]) or CMPBUF (TIMERx_PWMCMPBUF[15:0]) after current counter
count is completed. If the update PERIOD value is less than current counter value, counter will
count wraparound. The following steps are the sequence of Figure 6.17-7.
1. User writes CMP DATA1 at point 1 and hardware will load CMP DATA1 to CMPBUF after
current counter count is completed.
2. User writes PERIOD DATA1 at point 2 and PERIOD DATA1 is greater than current counter
value, PWM counter will continuously count until equal to PERIOD DATA1 to complete one
PWM period.
3. User writes PERIOD DATA2 at point 3 and PERIOD DATA2 is less than the current counter
value, PWM counter will continuously count to maximum counter value 0x1FFFF and
wraparound from 0x10000 to PERIOD DATA2 to complete one PWM period.
May 05, 2017
Page 112 of 161
Rev 1.00