5 Absolute Maximum Ratings
Under no circumstances must the absolute maximum ratings given in Table 2 be violated. Stress
exceeding one or more of the limiting values may cause permanent damage to the device.
Parameter
Supply voltage
Voltage on any digital pin
Voltage on the 1.8V pins (pin no.
22, 25-40 and 42)
Input RF level
Storage temperature range
Reflow soldering temperature
Min
Max
Units Condition
–0.3
3.6
V
All supply pins must have the same voltage
–0.3
VDD+0.3,
V
max 3.6
–0.3
2.0
V
10
dBm
–50
150
°C Device not programmed
260
°C According to IPC/JEDEC J-STD-020C
Table 2: Absolute Maximum Ratings
Caution! ESD sensitive device.
Precaution should be used when handling
the device in order to prevent permanent
damage.
6 Operating Conditions
The operating conditions for CC2430 are listed Table 3 in below.
Parameter
Operating ambient temperature
range, TA
Operating supply voltage
Min
Max
Unit Condition
-40
85
°C
2.0
3.6
V The supply pins to the radio part must be driven
by the on-chip regulator
Table 3: Operating Conditions
CC2430 PRELIMINARY Data Sheet (rev. 1.03) SWRS036A