NS32FX100-15 Datasheet, PDF (10/94 Pages) National Semiconductor (TI) – System Controller | |||
|
◁ |
2 0 Architecture
2 1 MCFG MODULE CONFIGURATION REGISTER
The software can configure some of the NS32FX100 major
operation modes by programming the Module Configuration
Register (MCFG) Some of the bits in this register are also
used to initialize the TPH block in the PRNTC the bitmap
shfiter block in the PRNTC and the scanner module When
a bit in the MCFG is ââ0ââ the associated module is idle
Setting a bit to ââ1ââ enables the operation of the associated
module Prior to activating a module its appropriate regis-
ters must be initialized by software
15
65
4
3
2
1
0
res
ESDC EDMA0 ESCAN EPBMS ETPHB ECOUNT
ECOUNT Enable internal counters of the TCU module
Once set this bit can not be cleared by software
The TCU counters except TIMER and WDC
must be initialized prior to setting this bit since
they start working when the ECOUNT bit is set
ETPHB
Enable Thermal Print-Head Block of the PRNTC
module The strobe-on and strobe-off counters
of this block must be initialized prior to setting
this bit to ââ1ââ
EPBMS
Enable Bitmap Shifter Block of the PRNTC mod-
ule Clearing this bit is treated by the Bitmap
Shifter as a hardware reset The block starts op-
erating when this bit is set When disabled DMA
channel 1 uses the printer PCLK DMRQ1 pin
ESCAN
Enable Scanner module Clearing this bit is treat-
ed by the Scanner Controller as a hardware re-
set The module starts operating when this bit is
set When cleared to ââ0ââ DMA channel 2 uses
the scanner pins and interrupt
EDMA0
Enable scanner usage of DMA channel 0 When
cleared to ââ0ââ DMA channel 0 uses the scanner
pins and interrupt
ESDC
Enable Sigma-Delta CODEC module When this
bit is set the SDC operation takes place as de-
scribed in Section 2 3
Upon reset the non reserved bits of the MCFG are cleared
to ââ0ââ thus disabling the above modules and options
2 2 TIMING CONTROL UNIT (TCU)
2 2 1 Features
Generation and control of clock running frequency
CPU and NS32FX100 synchronization by Phase Lock
Loop (PLL)
Fixed System-Tick interrupt of 100 Hz
WATCHDOG
Timer
Buzzer
Freeze mode
2 2 2 Operation
The Timing Control Unit (TCU) is responsible for generating
the clocks used for the various timing and counting func-
tions in the system and for freeze mode operation Figure
2-1 shows how the clocks are connected in an NS32FX100-
based FAX system
FIGURE 2-1 Clocks and Traps Connectivity
TL EE 11331 â 6
10
|
▷ |