English
Language : 

DS90UH947-Q1 Datasheet, PDF (40/87 Pages) Texas Instruments – 1080p OpenLDI to FPD-Link III Serializer with HDCP
DS90UH947-Q1
SNLS455 – NOVEMBER 2014
ADD
(dec)
7
ADD
(hex)
0x07
Register Name
Slave ID[0]
8
0x08 Slave Alias[0]
10
0x0A CRC Errors
11
0x0B
12
0x0C General Status
www.ti.com
Table 10. Serial Control Bus Registers (continued)
Bit(s)
7:1
0
7:1
0
7:0
7:0
7:4
3
2
1
0
Register
Type
RW
RW
R
R
R
R
R
R
Default
(hex)
0x00
0x00
0x00
0x00
0x00
Function
Description
Slave ID 0
Port0/Port1
Slave Alias ID 0
Port0/Port1
CRC Error LSB
Port0/Port1
CRC Error MSB
Port0/Port1
BIST CRC Error
Port0/Port1
PCLK Detect
DES Error
Port0/Port1
LINK Detect
Port0/Port1
7-bit I2C address of the remote Slave 0 attached to the remote
Deserializer. If an I2C transaction is addressed to Slave Alias ID 0, the
transaction will be remapped to this address before passing the
transaction across the Bidirectional Control Channel to the
Deserializer. A value of 0 in this field disables access to the remote
Slave 0.
If PORT1_SEL is set, this field refers to Port1 operation.
Reserved.
7-bit Slave Alias ID of the remote Slave 0 attached to the remote
Deserializer. The transaction will be remapped to the address
specified in the Slave ID 0 register. A value of 0 in this field disables
access to the remote Slave 0.
If PORT1_SEL is set, this field refers to Port1 operation.
Reserved.
Number of back channel CRC errors – 8 least significant bits. Cleared
by 0x04[5].
If PORT1_SEL is set, this field refers to Port1 operation.
Number of back channel CRC errors – 8 most significant bits. Cleared
by 0x04[5].
If PORT1_SEL is set, this field refers to Port1 operation.
Reserved.
Back channel CRC error(s) during BIST communication with
Deserializer. This bit is cleared upon loss of link, restart of BIST, or
assertion of CRC Error Reset bit in 0x04[5].
0: No CRC errors detected during BIST.
1: CRC error(s) detected during BIST.
If PORT1_SEL is set, this field refers to Port1 operation.
Pixel clock status:
0: Valid PCLK not detected at OpenLDI input.
1: Valid PCLK detected at OpenLDI input.
CRC error(s) during normal communication with Deserializer. This bit
is cleared upon loss of link or assertion of 0x04[5].
0: No CRC errors detected.
1: CRC error(s) detected.
If PORT1_SEL is set, this field refers to Port1 operation.
LINK detect status:
0: Cable link not detected.
1: Cable link detected.
If PORT1_SEL is set, this field refers to Port1 operation.
40
Submit Documentation Feedback
Product Folder Links: DS90UH947-Q1
Copyright © 2014, Texas Instruments Incorporated