English
Language : 

SI5325C-C-GM Datasheet, PDF (149/178 Pages) Silicon Laboratories – ANY-FREQUENCY PRECISION CLOCKS
Clock Input Crosstalk Results: Test Conditions
Si53xx-RM
Jitter Band
155.52 MHz in,
622 MHz out,
For reference,
No crosstalk
155.521 MHz in, 155.521 MHz in, 155.521 MHz in, 155.521 MHz in,
622.084 MHz 622.084 MHz 622.084 MHz 622.084 MHz
out,
out,
out,
out,
No crosstalk 155.52 MHz
155.52 MHz
155.52 MHz
Xtalk,
Xtalk,
Xtalk,
99 Hz loop 6.72 kHz loop In digital hold
Bandwidth
Bandwidth
OC-48,
12 kHz to 20 MHz
262 fs
262 fs
269 fs
422 fs
255 fs
OC-192,
20 kHz to 80 MHz
287 fs
290 fs
296 fs
366 fs
280 fs
Broadband,
800 Hz to 80 MHz
285 fs
289 fs
298 fs
1,010 fs
Measurement conditions:
1. Using Si5365/66-EVB.
2. Clock input on CKIN1, a 0dBm sine wave from Rohde and Schwarz RF Generator, model SML03
3. Crosstalk interfering signal applied to CKIN3, a PECL output at 155.52 MHz
4. All differential, AC coupled signals
277 fs
Rev. 1.2
149