SI5335 Datasheet, PDF (14/47 Pages) Silicon Laboratories – WEB-CUSTOMIZABLE, ANY-FREQUENCY, ANY-OUTPUT QUAD CLOCK GENERATOR/BUFFER | |||
|
◁ |
Si5335
Table 10. itter Specifications, Clock Buffer Mode (PLL Bypass)*
(VDD = 1.8 V â5% to +10%, 2.5 V ±10%, or 3.3 V ±10%, TA = â40 to 85°C)
Parameter
Symbol
Test Condition
Min
Additive Phase Jitter
(12 kHzâ20 MHz)
0.7 V pk-pk differential input
tRPHASE
clock at 350 MHz with
â
70 ps rise/fall time
Additive Phase Jitter
(50 kHzâ80 MHz)
0.7 V pk-pk differential input
tRPHASEWB clock at 350 MHz with
â
70 ps rise/fall time
*Note: All outputs are in Clock Buffer mode (PLL Bypass).
Typ
0.165
0.225
Max
Unit
â ps RMS
â ps RMS
Table 11. Typical Phase Noise Performance
Offset
Loop
25 MHz XTAL 27 MHz Ref In 19.44 MHz Ref In 100 MHz Ref In Units
Frequency Bandwidth to 156.25 MHz to 148.3517 MHz to 155.52 MHz
to 100 MHz
100 Hz
1.6 MHz
â90
â87
â110
â115
dBc/Hz
475 kHz
N/A*
â91
â91
â113
dBc/Hz
1 kHz
1.6 MHz
â120
â117
â116
â122
dBc/Hz
475 kHz
N/A*
â112
â111
â122
dBc/Hz
10 kHz
1.6 MHz
â126
â123
â123
â128
dBc/Hz
475 kHz
N/A*
â124
â122
â127
dBc/Hz
100 kHz
1.6 MHz
â132
â130
â128
â136
dBc/Hz
475 kHz
N/A*
â122
â121
â124
dBc/Hz
1 MHz
1.6 MHz
â132
â132
â128
â136
dBc/Hz
475 kHz
N/A*
â133
â131
â135
dBc/Hz
10 MHz
1.6 MHz
â145
â145
â145
â152
dBc/Hz
475 kHz
N/A*
â152
â153
â152
dBc/Hz
*Note: XTAL input mode does not support the 475 kHz loop bandwidth setting.
Table 12. Thermal Characteristics
Parameter
Thermal Resistance
Junction to Ambient
Thermal Resistance
Junction to Case
Symbol
ï±JA
ï±JC
Test Condition
Still Air
Still Air
Value
37
25
Unit
°C/W
°C/W
14