English
Language : 

AR0330 Datasheet, PDF (20/77 Pages) ON Semiconductor – CMOS Digital Image Sensor
AR0330: 1/3-Inch CMOS Digital Image Sensor
Electrical Characteristics
Two-Wire Serial Register Interface
The electrical characteristics of the two-wire serial register interface (SCLK, SDATA) are
shown in Figure 8 and Table 14.
Figure 8: Two-Wire Serial Bus Timing Parameters
Note:
Read sequence: For an 8-bit READ, read waveforms start after WRITE command and register
address are issued.
Table 14:
Two-Wire Serial Bus Characteristics
fEXTCLK = 27 MHz; VDD = 1.8V; VDD_IO = 2.8V; VAA = 2.8V; VAA_PIX = 2.8V;
VDD_PLL = 2.8V; TA = 25°C
Standard Mode
Fast Mode
Parameter
Symbol
Min
SCLK Clock Frequency
fSCL
0
Hold time (repeated) START condition
After this period, the first clock pulse is
tHD;STA
4.0
generated
LOW period of the SCLK clock
tLOW
4.7
HIGH period of the SCLK clock
tHIGH
4.0
Set-up time for a repeated START
tSU;STA
4.7
condition
Data hold time
tHD;DAT
04
Data set-up time
tSU;DAT
250
Rise time of both SDATA and SCLK signals
tr
-
Fall time of both SDATA and SCLK signals
tf
-
Set-up time for STOP condition
tSU;STO
4.0
Bus free time between a STOP and START
tBUF
4.7
condition
Capacitive load for each bus line
Cb
-
Serial interface input pin capacitance
CIN_SI
-
SDATA max load capacitance
CLOAD_SD
-
SDATA pull-up resistor
RSD
1.5
Max
Min
Max
Unit
100
0
400
KHz
-
0.6
-
s
-
1.3
-
s
-
0.6
-
s
-
0.6
-
s
3.455
-
06
1006
0.95
s
-
ns
1000
20 + 0.1Cb7
300
ns
300
20 + 0.1Cb7
300
ns
-
0.6
-
s
-
1.3
-
s
400
-
400
pF
3.3
-
3.3
pF
30
-
30
pF
4.7
1.5
4.7
K
Notes:
1. This table is based on I2C standard (v2.1 January 2000). Philips Semiconductor.
2. Two-wire control is I2C-compatible.
3. All values referred to VIHmin = 0.9 VDD and VILmax = 0.1VDD levels. Sensor EXCLK = 27 MHz.
AR0330_DS Rev. U Pub. 4/15 EN
20
©Semiconductor Components Industries, LLC,2015.