English
Language : 

LTC3882_15 Datasheet, PDF (98/104 Pages) Linear Technology – Dual Output PolyPhase Step-Down DC/DC Voltage Mode Controller with Digital Power System Management
LTC3882
PMBus COMMAND DETAILS (Fault Response and Communication)
MFR_FAULT_LOG
The MFR_FAULT_LOG command allows the contents of the fault log to be read. This log is created with a
MFR_FAULT_LOG_STORE command or at the first fault occurrence after a CLEAR_FAULTS or MFR_FAULT_LOG_CLEAR
command. If a fault occurs within the first second after applying power, some earlier pages in the log may not contain
valid data.
This read-only command uses block protocol with 147 bytes of data requiring an estimated data transfer time of 3.4ms
at 400kHz. The tTIMEOUT parameter is extended when this command is executed and a fault log is present.
MFR_FAULT_LOG_CLEAR
The MFR_FAULT_LOG_CLEAR command erases all stored fault log values. After a clear is issued, up to 8ms may be
required to clear related bit 3 in STATUS_MFR_SPECIFIC.
This write-only command has no data bytes.
EEPROM USER ACCESS
COMMAND NAME
CMD
CODE DESCRIPTION
STORE_USER_ALL
0x15 Store entire operating memory in EEPROM.
RESTORE_USER_ALL
0x16 Restore entire operating memory from
EEPROM.
MFR_COMPARE_USER_ALL
0xF0 Compare operating memory with EEPROM
contents.
MFR_FAULT_LOG_STORE
0xEA Force transfer of fault log from operating
memory to EEPROM.
MFR_EE_UNLOCK
0xBD (contact the factory)
MFR_EE_ERASE
0xBE (contact the factory)
MFR_EE_DATA
0xBF (contact the factory)
USER_DATA_00
0xB0 EEPROM word reserved for LTpowerPlay.
USER_DATA_01
0xB1 EEPROM word reserved for LTpowerPlay.
USER_DATA_02
0xB2 EEPROM word reserved for OEM use.
USER_DATA_03
0xB3 EEPROM word available for general data
storage.
USER_DATA_04
0xB4 EEPROM word available for general data
storage.
Related commands: MFR_CONFIG_ALL_LTC3882
DATA
TYPE PAGED FORMAT
Send Byte N
Send Byte N
UNITS NVM
DEFAULT
VALUE
NA
NA
Send Byte N
Send Byte N
R/W Word N
Reg
R/W Word Y
Reg
R/W Word N
Reg
R/W Word Y
Reg
R/W Word N
Reg
l
l
l
l 0x0000
l 0x0000
Note that if the LTC3882 die temperature exceeds 130°C, execution of any command in the above table except RE-
STORE_USER_ALL and MFR_FAULT_LOG_STORE will be disabled until the IC temperature drops below 125°C. RE-
STORE_USER_ALL is executed immediately, and MFR_FAULT_LOG_STORE is executed after the IC temperature drops
below 125°C. Refer to Table 4 for details of fault log contents. Using any command that writes data to the EEPROM is
strongly discouraged if bit 6 of STATUS_MFR_ SPECIFIC is set, indicating the internal die temperature is above 85°C.
Data retention of 10 years is not guaranteed if the EEPROM is written above a junction temperature of 85°C.
3882f
98