LTC3882
PMBus COMMAND DETAILS (Addressing and Write Protect)
MFR_ADDRESS
The MFR_ADDRESS command sets the seven bits of the PMBus device address for this unit (right justified).
Setting this command to a value of 0x80 disables device-level addressing. The GLOBAL device addresses 0x5A and 0x5B
cannot be disabled. The LTC3882 always responds at these addresses. Even if bit 6 of MFR_CONFIG_ALL_LTC3882 is
set to ignore the device resistor configuration pins, any valid address, or portion of an address, specified with external
resistors on ASEL0 or ASEL1 is applied. If both of these pins are open, the device address is determined strictly by
the MFR_ADDRESS value stored in EEPROM. Refer to the Operation section on Resistor Configuration Pins for ad-
ditional details.
This command has one data byte.
MFR_RAIL_ADDRESS
The MFR_RAIL_ADDRESS command sets a direct 7-bit PMBus address (right justified) for the active channel(s) as
determined by the PAGE command. This address should be common to all channels attached to a single power supply
rail. Setting this command to a value of 0x80 disables rail device addressing for the selected channel. Only command
writes should be made to the rail address. If a read is performed from this address, a CML fault may result.
This command has one data byte.
GENERAL DEVICE CONFIGURATION
COMMAND NAME
CMD
CODE DESCRIPTION
PMBUS_REVISION
0x98 Supported PMBus version.
CAPABILITY
MFR_CONFIG_ALL_LTC3882
0x19 Summary of supported optional PMBus
features.
0xD1 LTC3882 device-level configuration.
TYPE
R Byte
R Byte
DATA
DEFAULT
PAGED FORMAT UNITS NVM VALUE
Y
Reg
0x22
V1.2
N
Reg
0xB0
R/W Byte N
Reg
l
0x01
PMBUS_REVISION
The PMBUS_REVISION command returns the revision of the PMBus Specification that the device supports. The LTC3882
is compliant with PMBus Version 1.2, both Part I and Part II.
This read-only command has one data byte.
CAPABILITY
The CAPABILITY command reports some key LTC3882 features to the PMBus host device.
The LTC3882 supports packet error checking, 400kHz bus speeds and has an ALERT output.
This read-only command has one data byte.
3882f