LTC3882_15 Datasheet, PDF (91/104 Pages) Linear Technology – Dual Output PolyPhase Step-Down DC/DC Voltage Mode Controller with Digital Power System Management | |||
|
◁ |
LTC3882
PMBus COMMAND DETAILS (Fault Response and Communication)
FAULT RESPONSE AND COMMUNICATION
COMMAND NAME
CMD
CODE DESCRIPTION
DATA
DEFAULT
TYPE PAGED FORMAT UNITS NVM VALUE
VIN_OV_FAULT_RESPONSE
0x56 VIN overvoltage fault response.
R/W Byte Y
Reg
l
0x80
VOUT_OV_FAULT_RESPONSE
0x41 VOUT overvoltage fault response.
R/W Byte Y
Reg
l
0xB8
VOUT_UV_FAULT_RESPONSE
0x45 VOUT undervoltage fault response.
R/W Byte Y
Reg
l
0xB8
IOUT_OC_FAULT_RESPONSE
0x47 Output overcurrent fault response.
R/W Byte Y
Reg
l
0x00
OT_FAULT_RESPONSE
0x50 External overtemperature fault response.
R/W Byte Y
Reg
l
0xB8
UT_FAULT_RESPONSE
0x54 External undertemperature fault response. R/W Byte Y
Reg
l
0xB8
MFR_OT_FAULT_RESPONSE
0xD6 Internal overtemperature fault response.
R/W Byte N
Reg
l
0xC0
TON_MAX_FAULT_RESPONSE
0x63 Fault response when
TON_MAX_FAULT_LIMIT is exceeded.
R/W Byte Y
Reg
l
0xB8
MFR_RETRY_DELAY
0xDB Minimum time before retry after a fault.
R/W Word N
L11
ms l 350ms
0xFABC
SMBALERT_MASK
0x1B Mask ALERT Activity.
Block R/W Y
Reg
l See CMD
Details
MFR_GPIO_PROPAGATE
0xD2 Configure status propagation via GPIOn pins. R/W Word Y
Reg
l 0x6993
MFR_GPIO_RESPONSE
0xD5 PWM response when GPIOn pin is low.
R/W Byte Y
Reg
l
0xC0
MFR_FAULT_LOG
0xEE Read fault log data.
R Block N
Reg
MFR_FAULT_LOG_CLEAR
0xEC Clear existing EEPROM fault log.
Send Byte N
Related commands: STATUS_BYTE, STATUS_WORD, MFR_PADS_LTC3882, MFR_RESTART_DELAY, MFR_CHAN_CONFIG_LTC3882, MFR_FAULT_LOG_
STORE, CLEAR_FAULTS
These commands detail programmable device responses for detected faults beyond the hardware-level actions described
in the Operations section. LTC3882 hardware-level fault responses cannot be modified. Refer to Table 1 to Table 4 for
details of fault log contents. PMBus warning event responses are listed under _WARN_LIMIT command details.
VIN_OV_FAULT_RESPONSE
The VIN_OV_FAULT_RESPONSE command instructs the device on what action to take in response to an input overvolt-
age fault. The format for this command is given in Table 13. The device also:
⢠Sets the INPUT Bit in the STATUS_WORD
⢠Sets the VIN Overvoltage Fault Bit in the STATUS_INPUT Command
⢠Notifies the Host by Asserting ALERT, Unless Masked
This command has one data byte.
For more information www.linear.com/LTC3882
3882f
91
|
▷ |