82P33714 Datasheet
Table 32: SONET/SDH Output Clock Jitter Generation
(jitter measured on one differential output of APLL1/2 with one differential output enabled
Output Frequency
RMS Jitter Typ (ps)
RMS Jitter Max (ps)
0.58
0.83
0.51
0.66
0.16
0.26
622.08 MHz
1.05
1.52
0.97
1.44
0.73
1.06
0.29
0.39
0.20
0.28
0.14
0.27
NOTE 1: DPLL locked to input clock
Test Filter
12 kHz to 20 MHz
20 kHz to 80 MHz
4 MHz to 80 MHz
500 Hz to 1.3 MHz
1 kHz to 5 MHz
5 kHz to 20 MHz
65 kHz to 1.3 MHz
250 kHz to 5 MHz
1 MHz to 20 MHz
Notes
GR-253-CORE and ITU-T
G.813 Option 2
limit 0.1 UI p-p /
0.01 UI RMS
(STM-16: 1UI = 0.40 ns)
GR-253-CORE and ITU-T
G.813 Option 2
limit 0.3 UI p-p
(STM-64: 1 UI = 0.10 ns)
ITU-T G.813 Option 1
limit 0.5 UI p-p
(STM-64: 1 UI = 0.10 ns)
GR-253-CORE and ITU-T
G.813 Option 2
limit 0.1 UI p-p
(STM-64: 1 UI = 0.10 ns)
ITU-T G.813 Option 1
limit 0.1 UI p-p
(STM-64: 1 UI = 0.10 ns)
ITU-T G.813 Option 1
limit 0.5 UI p-p
(STM-1: 1 UI = 6.43 ns)
ITU-T G.813 Option 1
limit 0.5 UI p-p
(STM-4: 1 UI = 1.61 ns)
ITU-T G.813 Option 1
limit 0.5 UI p-p
(STM-16: 1UI = 0.40 ns)
ITU-T G.813 Option 1
limit 0.1 UI p-p
(STM-1: 1 UI = 6.43 ns)
ITU-T G.813 Option 1
limit 0.1 UI p-p
(STM-4: 1 UI = 1.61 ns)
ITU-T G.813 Option 1
limit 0.1 UI p-p
(STM-16: 1UI = 0.40 ns)
©2017 Integrated Device Technology, Inc.
57
Revision 6, January 23, 2017