English
Language : 

ICS1893Y-10 Datasheet, PDF (98/150 Pages) –
ICS1893Y-10 Data Sheet - Release
Chapter 7 Management Register Set
7.13.2 Polarity Reversed (bit 18.14)
The Polarity Reversed bit is used to inform an STA whether the ICS1893Y-10 has detected that the signals
on the Twisted-Pair Receive Pins (TP_RXP and TP_RXN) are reversed. When the signal polarity is:
• Correct, the ICS1893Y-10 sets bit 18.14 to a logic zero.
• Reversed, the ICS1893Y-10 sets bit 18.14 to logic one.
Note: The ICS1893Y-10 can detect this situation and perform all its operations normally, independent of
the reversal.
7.13.3 ICS Reserved (bits 18.13:6)
See Section 7.11.2, “ICS Reserved (bits 16.14:11)”, the text for which also applies here.
7.13.4 Jabber Inhibit (bit 18.5)
The Jabber Inhibit bit allows an STA to disable Jabber Detection. When an STA sets this bit to:
• Zero, the ICS1893Y-10 enables 10Base-T Jabber checking.
• One, the ICS1893Y-10 disables its check for a Jabber condition during data transmission.
7.13.5 ICS Reserved (bit 18.4)
See Section 7.11.2, “ICS Reserved (bits 16.14:11)”, the text for which also applies here.
7.13.6 Auto Polarity Inhibit (bit 18.3)
The Auto Polarity Inhibit bit allows an STA to prevent the automatic correction of a polarity reversal on the
Twisted-Pair Receive pins (TP_RXP and TP_RXN). If an STA sets this bit to logic:
• Zero (the default), the ICS1893Y-10 automatically corrects a polarity reversal on the Twisted-Pair
Receive pins.
• One, the ICS1893Y-10 either disables or inhibits the automatic correction of reversed Twisted-Pair
Receive pins.
Note: This bit is also used to correct a reversed signal polarity for 100Base-TX operations.
7.13.7 SQE Test Inhibit (bit 18.2)
The SQE Test Inhibit bit allows an STA to prevent the generation of the Signal Quality Error pulse. When an
STA sets this bit to logic:
• Zero, the ICS1893Y-10 enables its SQE Test generation.
• One, the ICS1893Y-10 disables its SQE Test generation.
The SQE Test provides the ability to verify that the Collision Logic is active and functional. A 10Base-T SQE
test is performed by pulsing the Collision signal for a short time after each packet transmission completes,
that is, after TXEN goes inactive.
Note:
1. The SQE Test is automatically inhibited in full-duplex and repeater modes, thereby disabling the
functionality of this bit.
2. This bit is a control bit and not a status bit. Therefore, it is not updated to indicate this automatic
inhibiting of the SQE test in full-duplex mode or repeater mode.
ICS1893Y-10 Rev F 1/20/04
Copyright © 2004, Integrated Circuit Systems, Inc.
All rights reserved.
98
January, 2004