English
Language : 

ICS1893Y-10 Datasheet, PDF (121/150 Pages) –
ICS1893Y-10 - Release
Chapter 9 DC and AC Operating Conditions
Chapter 9 DC and AC Operating Conditions
9.1 Absolute Maximum Ratings
Table 9-1 lists absolute maximum ratings. Stresses above these ratings can permanently damage the
ICS1893Y-10. These ratings, which are standard values for ICS commercially rated parts, are stress
ratings only. Functional operation of the ICS1893Y-10 at these or any other conditions above those
indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods can affect product reliability. Electrical parameters are guaranteed
only over the range of the recommended operating temperature.
Table 9-1. Absolute Maximum Ratings for ICS1893Y-10
Item
VDD (measured to VSS)
Digital Inputs / Outputs
Storage Temperature
Junction Temperature
Soldering Temperature
Power Dissipation
Rating
-0.3 V to 3.6V
-0.3 V to VDD +0.3 V
-55° C to +150° C
125° C
260° C
See Section 9.4.1, “DC Operating Characteristics for Supply Current”
9.2 Recommended Operating Conditions
Table 9-2. Recommended Operating Conditions for ICS1893Y-10
Parameter
Symbols
Ambient Operating Temperature - Commercial
Ambient Operating Temperature - Industrial
Power Supply Voltage (measured to VSS)
TA
TA
VDD
Min.
0
-40
+3.14
Max.
+70
+85
+3.47
Units
°C
°C
V
ICS1893Y-10 Rev F 1/20/04
Copyright © 2004, Integrated Circuit Systems, Inc.
All rights reserved.
121
January, 2004