Chapter 9 DC and AC Operating Conditions
9.5.14 10M MII: Carrier Assertion/De-Assertion (Half-Duplex Transmission)
Table 9-21 lists the significant time periods for the 10M MII carrier assertion/de-assertion during half-duplex
transmission. The time periods consist of timings of signals on the following pins:
• TXEN
• TXCLK
• CRS
Figure 9-15 shows the timing diagram for the time periods.
Table 9-21. 10M MII Carrier Assertion/De-Assertion (Half-Duplex Transmission Only)
Time
Period
Parameter
t1 TXEN Asserted to CRS Assert
t2 TXEN De-Asserted to CRS De-Asserted
Condi- Min.
tions
0
0
Typ.
–
2
Max. Units
2 Bit times
4 Bit times
Figure 9-15. 10M MII Carrier Assertion/De-Assertion Timing Diagram
(Half-Duplex Transmission Only)
t2
TXEN
TXCLK
CRS
t1