English
Language : 

ICS1893Y-10 Datasheet, PDF (144/150 Pages) –
ICS1893Y-10 Data Sheet - Release
Chapter 9 DC and AC Operating Conditions
9.5.20 10Base-T: Jabber Timing
Table 9-27 lists the significant time periods for the 10Base-T jabber. The time periods consist of timings of
signals on the following pins:
• TXEN
• TP_TX (that is, TP_TXP and TP_TXN)
• COL
Figure 9-21 shows the timing diagram for the time periods.
Note: For more information on 10Base-T jabber operations, see Section 6.5.9, “10Base-T Operation:
Jabber”.
Table 9-27. 10Base-T Jabber Timing
Time
Period
Parameter
t1 Jabber Activation Time
t2 Jabber De-Activation Time
Conditions
10Base-T Half Duplex
10Base-T Half Duplex
Min. Typ. Max. Units
20
–
35 ms
300 – 325 ms
Figure 9-21. 10Base-T Jabber Timing Diagram
TXEN
t1
TP_TX
t2
COL
ICS1893Y-10 Rev F 1/20/04
Copyright © 2004, Integrated Circuit Systems, Inc.
All rights reserved.
144