English
Language : 

MC68HC908GR8 Datasheet, PDF (82/286 Pages) Freescale Semiconductor, Inc – M68HC08 Microcontrollers
Clock Generator Module (CGMC)
7.5.2 PLL Bandwidth Control Register
The PLL bandwidth control register (PBWC):
• Selects automatic or manual (software-controlled) bandwidth control mode
• Indicates when the PLL is locked
• In automatic bandwidth control mode, indicates when the PLL is in acquisition or tracking mode
• In manual operation, forces the PLL into acquisition or tracking mode
Address:
Read:
Write:
Reset:
$0037
Bit 7
AUTO
0
6
5
LOCK
ACQ
0
0
= Unimplemented
4
3
2
0
0
0
0
0
0
R = Reserved
1
Bit 0
0
R
0
0
Figure 7-5. PLL Bandwidth Control Register (PBWC)
AUTO — Automatic Bandwidth Control Bit
This read/write bit selects automatic or manual bandwidth control. When initializing the PLL for manual
operation (AUTO = 0), clear the ACQ bit before turning on the PLL. Reset clears the AUTO bit.
1 = Automatic bandwidth control
0 = Manual bandwidth control
LOCK — Lock Indicator Bit
When the AUTO bit is set, LOCK is a read-only bit that becomes set when the VCO clock, CGMVCLK,
is locked (running at the programmed frequency). When the AUTO bit is clear, LOCK reads as 0 and
has no meaning. The write one function of this bit is reserved for test, so this bit must always be written
a 0. Reset clears the LOCK bit.
1 = VCO frequency correct or locked
0 = VCO frequency incorrect or unlocked
ACQ — Acquisition Mode Bit
When the AUTO bit is set, ACQ is a read-only bit that indicates whether the PLL is in acquisition mode
or tracking mode. When the AUTO bit is clear, ACQ is a read/write bit that controls whether the PLL is
in acquisition or tracking mode.
In automatic bandwidth control mode (AUTO = 1), the last-written value from manual operation is
stored in a temporary location and is recovered when manual operation resumes. Reset clears this bit,
enabling acquisition mode.
1 = Tracking mode
0 = Acquisition mode
MC68HC908GR8 • MC68HC908GR4 Data Sheet, Rev. 7
82