English
Language : 

LM3S1621 Datasheet, PDF (270/947 Pages) Texas Instruments – ARM and Thumb are registered trademarks and Cortex is a trademark
System Control
Bit/Field
17
16
15
14
13
12
11:6
5
4
3
2
1
Name
TIMER1
TIMER0
reserved
I2C1
reserved
I2C0
reserved
SSI1
SSI0
reserved
UART2
UART1
Type
R/W
R/W
RO
R/W
RO
R/W
RO
R/W
R/W
RO
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
Description
Timer 1 Reset Control
When this bit is set, General-Purpose Timer module 1 is reset. All internal
data is lost and the registers are returned to their reset states. This bit
must be manually cleared after being set.
Timer 0 Reset Control
When this bit is set, General-Purpose Timer module 0 is reset. All internal
data is lost and the registers are returned to their reset states. This bit
must be manually cleared after being set.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
I2C1 Reset Control
When this bit is set, I2C module 1 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
I2C0 Reset Control
When this bit is set, I2C module 0 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
SSI1 Reset Control
When this bit is set, SSI module 1 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
SSI0 Reset Control
When this bit is set, SSI module 0 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
UART2 Reset Control
When this bit is set, UART module 2 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
UART1 Reset Control
When this bit is set, UART module 1 is reset. All internal data is lost and
the registers are returned to their reset states. This bit must be manually
cleared after being set.
270
January 21, 2012
Texas Instruments-Production Data