English
Language : 

MSP430FR5729 Datasheet, PDF (25/115 Pages) Texas Instruments – MSP430FR572x Mixed-Signal Microcontrollers
www.ti.com
MSP430FR5729, MSP430FR5728, MSP430FR5727, MSP430FR5726, MSP430FR5725
MSP430FR5724, MSP430FR5723, MSP430FR5722, MSP430FR5721, MSP430FR5720
SLASE35A – MAY 2014 – REVISED JUNE 2014
5.17 PMM, Core Voltage
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
VCORE(AM)
Core voltage, active mode
2 V ≤ DVCC ≤ 3.6 V
1.5
VCORE(LPM)
Core voltage, low-current mode
2 V ≤ DVCC ≤ 3.6 V
1.5
MAX
UNIT
V
V
5.18 PMM, SVS, BOR
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
ISVSH,AM
ISVSH,LPM
VSVSH-
VSVSH+
tPD,SVSH, AM
tPD,SVSH, LPM
ISVSL
VSVSL–
VSVSL+
SVSH current consumption, active mode
SVSH current consumption, low power modes
SVSH on voltage level, falling supply voltage
SVSH off voltage level, rising supply voltage
SVSH propagation delay, active mode
SVSH propagation delay, low power modes
SVSL current consumption
SVSL on voltage level
SVSL off voltage level
VCC = 3.6 V
VCC = 3.6 V
dVCC/dt = 10 mV/µs
dVCC/dt = 1 mV/µs
5
0.8
1.83
1.88
1.88
1.93
10
30
0.3
1.42
1.47
MAX UNIT
µA
1.5 µA
1.93 V
1.98 V
µs
µs
0.5 µA
V
V
5.19 Wake-Up from Low Power Modes
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
tWAKE-UP LPM0
PARAMETER
Wake-up time from LPM0 to active
mode (1)
TEST CONDITIONS
VCC
TA
2 V, 3 V
-40°C to 85°C
MIN TYP MAX UNIT
0.58
1 µs
tWAKE-UP LPM12
Wake-up time from LPM1, LPM2 to
active mode (1)
2 V, 3 V
-40°C to 85°C
12
25 µs
tWAKE-UP LPM34
Wake-up time from LPM3 or LPM4 to
active mode (1)
2 V, 3 V
-40°C to 85°C
78 120 µs
tWAKE-UP LPMx.5
Wake-up time from LPM3.5 or
LPM4.5 to active mode (1)
2 V, 3 V
0°C to 85°C
2 V, 3 V
-40°C to 85°C
310 575 µs
310 1100 µs
tWAKE-UP RESET
Wake-up time from RST to active
mode (2)
VCC stable
2 V, 3 V
-40°C to 85°C
230 280 µs
tWAKE-UP BOR
Wake-up time from BOR or power-up
to active mode
dVCC/dt = 2400 V/s
2 V, 3 V
-40°C to 85°C
1.6
ms
tRESET
Pulse duration required at RST/NMI
terminal to accept a reset event(3)
2 V, 3 V
-40°C to 85°C
4
ns
(1) The wake-up time is measured from the edge of an external wake-up signal (for example, port interrupt or wake-up event) until the first
instruction of the user program is executed.
(2) The wake-up time is measured from the rising edge of the RST signal until the first instruction of the user program is executed.
(3) Meeting or exceeding this time makes sures a reset event occurs. Pulses shorter than this minimum time may or may not cause a reset
event to occur.
Copyright © 2014, Texas Instruments Incorporated
Specifications
25
Submit Documentation Feedback
Product Folder Links: MSP430FR5729 MSP430FR5728 MSP430FR5727 MSP430FR5726 MSP430FR5725
MSP430FR5724 MSP430FR5723 MSP430FR5722 MSP430FR5721 MSP430FR5720