English
Language : 

GR442QR7LB102KW01L Datasheet, PDF (180/237 Pages) Murata Manufacturing Co., Ltd. – chip monolithic ceramic capacitors
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
GR4 Series Specifications and Test Methods
C02E.pdf
Oct.1,2012
No.
Item
Specifications
1
Operating
Temperature Range
2 Appearance
3 Dimensions
–55 to +125°C
No defects or abnormalities
Within the specified dimensions
4 Dielectric Strength No defects or abnormalities
5 *ՏÃiÊ6œÌ>}i
No self healing breakdowns or flash-overs have taken place in
the capacitor.
6
Insulation Resistance
(I.R.)
More than 6,000MΩ
7 Capacitance
Within the specified tolerance
8
Dissipation
Factor (D.F.)
0.025 max.
Capacitance
9 Temperature
Characteristics
Cap. Change
within ±15%
(Temp. Range: –55 to +125°C)
10
Adhesive Strength
of Termination
No removal of the terminations or other defect should occur.
Appearance No defects or abnormalities
Capacitance Within the specified tolerance
11
Vibration
Resistance
D.F.
0.025 max.
Test Method
–
Visual inspection
Using calipers and micrometers
No failure should be observed when voltage in the table is
applied between the terminations, provided the charge/discharge
current is less than 50mA.
Rated Voltage
DC2kV
Test Voltage
120% of the rated voltage
AC1500V(r.m.s.)
Time
60±1 sec.
60±1 sec.
10 impulses of alternating polarity are subjected.
(5 impulses for each polarity)
The interval between impulses is 60 sec.
Applied Pulse: 1.2/50μs
Applied Voltage: 2.5kVo-p
The insulation resistance should be measured with DC500±50V
and within 60±5 sec. of charging.
The capacitance/D.F. should be measured at a frequency of
1±0.2kHz and a voltage of AC1±0.2V(r.m.s.).
The capacitance measurement should be made at each step
specified in the Table.
Step
1
2
3
4
5
Temperature (°C)
25±2
Min. Operating Temp.±3
25±2
Max. Operating Temp.±2
25±2
U*ÀiÌÀi>̓i˜Ì
Perform a heat treatment at 150W Y0 10°C for 60±5 min. and then
let sit for 24±2 hrs. at room condition.*
Solder the capacitor to the testing jig (glass epoxy board) shown
in Fig. 1.
Then apply 10N force in the direction of the arrow.
The soldering should be done using the reflow method and
should be conducted with care so that the soldering is uniform
and free of defects such as heat shock.
10N, 10±1s
Glass Epoxy Board
Fig. 1
Solder the capacitor to the test jig (glass epoxy board).
The capacitor should be subjected to a simple harmonic motion
having a total amplitude of 1.5mm, the frequency being varied
uniformly between the approximate limits of 10 and 55Hz. The
frequency range, from 10 to 55Hz and return to 10Hz, should be
traversed in approximately 1 min. This motion should be applied
for a period of 2 hrs. in each of 3 mutually perpendicular
directions (total of 6 hrs.).
Glass Epoxy Board
Solder resist
Cu
* "Room condition" Temperature: 15 to 35°C, Relative humidity: 45 to 75%, Atmospheric pressure: 86 to 106kPa
Continued on the following page.
162