English
Language : 

1EDI2002AS_15 Datasheet, PDF (104/147 Pages) Infineon Technologies AG – Single Channel Isolated Driver for Inverter Systems AD Step
Field
FLTA
PWM
0
LMI
P
EiceDRIVER™ SIL
1EDI2002AS
Register Description
Bits
Type Description
5
rh
Event Class A Error
This bit indicates if the conditions leading to an Event
Class A are detected.
0B: Event conditions are not met.
1B: Event conditions are met.
4
rh
PWM Command Status
This bit indicates the status of the PWM command
received from the primary side.
0B: PWM OFF command is detected.
1B: PWM ON command is detected.
3:2
r
Reserved
Read as 0B.
1
rh
Last Message Invalid Notification
This bit indicates if the last received SPI Message was
correctly processed by the device.
0B: Previous Message was processed correctly.
1B: Previous Message was discarded.
0
rh
Parity Bit
Odd Parity Bit.
Datasheet
104
Hardware Description
Rev. 3.1, 2015-07-30