English
Language : 

MC68HC908LJ12 Datasheet, PDF (242/413 Pages) Freescale Semiconductor, Inc – 8-bit microcontroller units
Infrared Serial Communications Interface Module (IRSCI)
NOTE:
The RT8, RT9, and RT10 samples do not affect start bit verification. If
any or all of the RT8, RT9, and RT10 start bit samples are logic 1s
following a successful start bit verification, the noise flag (NF) is set and
the receiver assumes that the bit is a start bit.
To verify a stop bit and to detect noise, recovery logic takes samples at
RT8, RT9, and RT10. Table 13-4 summarizes the results of the stop bit
samples.
Table 13-4. Stop Bit Recovery
RT8, RT9, and RT10
Samples
Framing
Error Flag
Noise Flag
000
1
0
001
1
1
010
1
1
011
0
1
100
1
1
101
0
1
110
0
1
111
0
0
13.7.3.4 Framing Errors
If the data recovery logic does not detect a logic 1 where the stop bit
should be in an incoming character, it sets the framing error bit, FE, in
SCS1. The FE flag is set at the same time that the SCRF bit is set. A
break character that has no stop bit also sets the FE bit.
13.7.3.5 Baud Rate Tolerance
A transmitting device may be operating at a baud rate below or above
the receiver baud rate. Accumulated bit time misalignment can cause
one of the three stop bit data samples to fall outside the actual stop bit.
Then a noise error occurs. If more than one of the samples is outside the
stop bit, a framing error occurs. In most applications, the baud rate
tolerance is much more than the degree of misalignment that is likely to
occur.
MC68HC908LJ12 — Rev. 2.1
Freescale Semiconductor Infrared Serial Communications Interface Module (IRSCI)
Technical Data