English
Language : 

MC68HC908LJ12 Datasheet, PDF (118/413 Pages) Freescale Semiconductor, Inc – 8-bit microcontroller units
Clock Generator Module (CGM)
PLLON — PLL On Bit
This read/write bit activates the PLL and enables the VCO clock,
CGMVCLK. PLLON cannot be cleared if the VCO clock is driving the
base clock, CGMOUT (BCS = 1). (See 8.4.8 Base Clock Selector
Circuit.) Reset sets this bit so that the loop can stabilize as the MCU
is powering up.
1 = PLL on
0 = PLL off
BCS — Base Clock Select Bit
This read/write bit selects either the oscillator output, CGMXCLK, or
the divided VCO clock, CGMPCLK, as the source of the CGM output,
CGMOUT. CGMOUT frequency is one-half the frequency of the
selected clock. BCS cannot be set while the PLLON bit is clear. After
toggling BCS, it may take up to three CGMXCLK and three
CGMPCLK cycles to complete the transition from one source clock to
the other. During the transition, CGMOUT is held in stasis. (See 8.4.8
Base Clock Selector Circuit.) Reset clears the BCS bit.
1 = CGMPCLK divided by two drives CGMOUT
0 = CGMXCLK divided by two drives CGMOUT
NOTE:
PLLON and BCS have built-in protection that prevents the base clock
selector circuit from selecting the VCO clock as the source of the base
clock if the PLL is off. Therefore, PLLON cannot be cleared when BCS
is set, and BCS cannot be set when PLLON is clear. If the PLL is off
(PLLON = 0), selecting CGMPCLK requires two writes to the PLL control
register. (See 8.4.8 Base Clock Selector Circuit.)
PRE1 and PRE0 — Prescaler Program Bits
These read/write bits control a prescaler that selects the prescaler
power-of-two multiplier, P. (See 8.4.3 PLL Circuits and 8.4.6
Programming the PLL.) PRE1 and PRE0 cannot be written when
the PLLON bit is set. Reset clears these bits.
These prescaler bits affects the relationship between the VCO clock
and the final system bus clock.
MC68HC908LJ12 — Rev. 2.1
Freescale Semiconductor
Clock Generator Module (CGM)
Technical Data
119