AK8140A
Example1) input 27MHz, output 54MHz
1. fVCO2: 108MHz
ODIVn = 2
2. M2: 1
N2: 4
As the highest common measure of fin2 and fvco2 is 27MHz
3. P:
2
={4-int(log24)}
N INT:
16
={int(4×22)/1 }
NNUME:
0
={4×22-1×16}
NDEMO:
1
={M=1}
∴MDIV = 22= 4, NDIV = 16 + (0/1) = 16
Example2) input 27MHz, output 24.576MHz
1. fVCO2: 221.184MHz ODIVn = 9
2. M2: 125
N2: 1024
As the highest common measure of fin2 and fvco2 is 0.216MHz
3. P:
N INT:
NNUME:
NDEMO:
1
={4-int(log2 (1204/125))}
16
={int(1024×21)/125 }
0
={1024×21-125×16}
125 ={M=125}
∴MDIV = 21= 2, NDIV = 16 + (48/125)