English
Language : 

W83793G Datasheet, PDF (98/131 Pages) Winbond – Winbond H/W Monitor
W83793G
And according to each channel status, they are expressed in the following terms.
DESCRIPTION
STATUS
TEMPERATURE SENSORS
Upper-Critical Going High
Upper-Critical Going Low
Upper-Non-critical
Going
High
Upper-Non-critical Going Low
Lower-Non-critical
Going
High
Lower-Non-critical Going Low
VOLTAGE SENSORS
3h
Assert
2h
Deasser
t
EVENT
SENSOR
TYPE
01h
Temperature
EVENT
TYPE
01h
Threshold-
Based
EVENT
OFFSET
09h
08h
07h
06h
01h
00h
Generic Over
Problem
Voltage 3h
Normal Voltage
2h
Generic Under
Problem
Voltage 3h
FAN SENSORS
Normal FAN Speed
2h
Generic FAN Failure
3h
02h
Voltage
04h
Fan
07h
02h
Generic- 07h
Severity
02h
07h
07h
02h
CASEOPEN/ CASE INTRUSION
EVENT
SEVERITY
10h
Critical
08h
Non-critical
01h
Monitor
10h
01h
10h
01h
10h
Case Intruded
Case Normal
3h
05h
6Fh
00h
10h
Physical
Sensor
2h
Security
Specific
80h
01h
8.13.1.3 ASF Remote Control Definition Registers
ASF function in W83793G also supports the Remote Control. This function enables MIS to remotely
power on, power down, or reset while he finds the client computer goes into abnormal.
MNEMONIC
PwrOnOption.
PwrOnCmd.
PwrOffCmd.
RstCmd.
REGISTER NAME
Power On Control Option Register
Remote Control Power On Command Register
Remote Control Power Down Command Register
Remote Control Reset Command Register
TYPE
RW
RW
RW
RW
Remote Control function in W83793G enables MIS to use side-band of Network Interface Controller to
send ASF commands with SMBus, its format looks like
- 94 -