English
Language : 

W83793G Datasheet, PDF (52/131 Pages) Winbond – Winbond H/W Monitor
W83793G
  VSEN1, VSEN2, 3VSEN Limit Setup
CR6A~6F =
[Desired Voltage] / 0.016;
  12VSEN Limit Setup
CR70~71 =
[Desired Voltage] / 0.08;
  5VDD, 5VSB Limit Setup
CR72~75
=
[Desired Voltage] / 0.024;
  VBAT Limit Setup
CR76~77
=
[Desired Voltage] / 0.016;
8.10 Temperature Channel Registers
8.10.1 Temperature Channel Register Map
8.10.1.1 Temperature Channel Monitored Value Register Map
MNEMONIC
REGISTER NAME
TD1.
Temperature Sensor TD1 Readout
TD2.
Temperature Sensor TD2 Readout
TD3.
Temperature Sensor TD3 Readout
TD4.
Temperature Sensor TD4 Readout
TDLowB.
Temperature Sensor TD Low Bit Readout
TR1.
Temperature Sensor TR1 Readout
TR2.
Temperature Sensor TR2 Readout
TYPE
RO
RO
RO
RO
RO
RO
RO
8.10.1.2 Temperature Channel Limitation Value Register Map
MNEMONIC
REGISTER NAME
TD1 CT/CTH. TD1 Critical Temperature / Critical Temperature Hysteresis
TD1 WT/WTH. TD1 Warning Temperature / Warning Temperature Hysteresis
TD2 CT/CTH.
TD2 WT/WTH.
TD3 CT/CTH.
TD2 Critical Temperature / Critical Temperature Hysteresis
TD2 Warning Temperature / Warning Temperature Hysteresis
TD3 Critical Temperature / Critical Temperature Hysteresis
TD3 WT/WTH.
TD4 CT/CTH.
TD4 WT/WTH.
TD3 Warning Temperature / Warning Temperature Hysteresis
TD4 Critical Temperature / Critical Temperature Hysteresis
TD4 Warning Temperature / Warning Temperature Hysteresis
TR1 CT/CTH. TR1 Critical Temperature / Critical Temperature Hysteresis
TYPE
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
- 48 -