English
Language : 

W83793G Datasheet, PDF (55/131 Pages) Winbond – Winbond H/W Monitor
W83793G
SENSOR CRITICAL TEMPERATURE HYSTERSIS
BIT
7
6
5
4
3
2
1
0
Name
Sensor Critical Temperature Hysteresis
Reset
5FHEX (95 C)
SENSOR CRITICAL TEMPERATURE
BIT
7
6
5
4
3
2
1
0
Name
Sensor Warning Temperature
Reset
55HEX (85 C)
SENSOR WARNING TEMPERATURE HYSTERSIS
BIT
7
6
5
4
3
2
1
0
Name
Sensor Warning Temperature Hysteresis
Reset
50HEX (80 C)
The format of Temperature channel limit is 2’complement, bit 7 is sign bit, range is –128~127.
8.11 Fan Control Registers
All Fan Control/Status register are allocated in Bank 0 and Bank 2. Bank 0 resides common-used
control/status registers, and Bank 2 inside has Smart Fan Control setups.
8.11.1 Fan Register Map
8.11.1.1 Common Register Control/Status registers Block
All common Fan Control/Status registers are located in Bank 0.
- 51 -
Publication Release Date: Dec. 11, 2006
Revision 1.0